Levelindicator besta

Levelindicator BESTA Levelindicator BESTA


Levelindicator Besta
Side-mounted level sensor for high or low alarm, incl. flange packing suitable for:
Control of pumps and valves
Overfill
Dry-running protection

 

When it is not desirable or possible to install float level sensor directly into the tank, TriMod BESTA level sensor can be mounted externally in a float chamber. This type of installation enables functional testing and service without operating break if the connection lines are provided with shut-off and drainage valves.

Levelindicator, compact Type C 01C 05
Side-mounted level sensor for high or low alarm, incl. gasket.


TECHNICAL DATA
Nominal pressure: PN 10
Working temperature: 0 to 150 ° C
Ambient temperature: 0 to 70 ° C
Density of the liquid: min. 0.7 kg / dm³
Dead zone: 12 mm, phase:
Fluid-affected parts: Stainless acid-proof steel (CrNiMo)
Flange material: Stainless acid-proof steel (CrNiMo)
Operating module (house): Sea-water-resistant cast aluminum
Flange: Square 92 x 92 mm, HC 92 mm
Contact insert: Micro switch SPDT with siver contacts
Breaking Capacity: 250 VAC, 3 A - 30 VDC, 0.5 A
Protection: IP65
Weight: approx. 0.9 kg
Cable screw: M20 x 1.5


There are several variants of BESTA.

If you can't find what you need on our website, contact us
Tel: +4660 61 11 25 or e-mail: info@absab.com







The easiest way to mount a TriMod BESTA compact level sensor is to use our standard counter flanges for Flange Dimension Wiring Schedule Welding. There are two different lengths of counter flanges in material C22.8 carbon steel or 1.4404 stainless steel, with or without test devices.